TY - JOUR
T1 - Chemical species separation with simultaneous estimation of field map and T2* using a k-space formulation
AU - Honorato, Jose Luis
AU - Parot, Vicente
AU - Tejos, Cristian
AU - Uribe, Sergio
AU - Irarrazaval, Pablo
PY - 2012/8
Y1 - 2012/8
N2 - Chemical species separation techniques in image space are prone to incorporate several distortions. Some of these are signal accentuation in borders and geometrical warping from field inhomogeneity. These errors come from neglecting intraecho time variations. In this work, we present a new approach for chemical species separation in MRI with simultaneous estimation of field map and T2* decay, formulated entirely in k-space. In this approach, the time map is used to model the phase accrual from off-resonance precession and also the amplitude decay due to T2 *. Our technique fits the signal model directly in k-space with the acquired data minimizing the l2-norm with an interior-point algorithm. Standard two dimensional gradient echo sequences in the thighs and head were used for demonstrating the technique. With this approach, we were able to obtain excellent estimation for the species, the field inhomogeneity, and T2* decay images. The results do not suffer from geometric distortions derived from the chemical shift or the field inhomogeneity. Importantly, as the T2* map is well positioned, the species signal in borders is correctly estimated. Considering intraecho time variations in a complete signal model in k-space for separating species yields superior estimation of the variables of interest when compared to existing methods. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
AB - Chemical species separation techniques in image space are prone to incorporate several distortions. Some of these are signal accentuation in borders and geometrical warping from field inhomogeneity. These errors come from neglecting intraecho time variations. In this work, we present a new approach for chemical species separation in MRI with simultaneous estimation of field map and T2* decay, formulated entirely in k-space. In this approach, the time map is used to model the phase accrual from off-resonance precession and also the amplitude decay due to T2 *. Our technique fits the signal model directly in k-space with the acquired data minimizing the l2-norm with an interior-point algorithm. Standard two dimensional gradient echo sequences in the thighs and head were used for demonstrating the technique. With this approach, we were able to obtain excellent estimation for the species, the field inhomogeneity, and T2* decay images. The results do not suffer from geometric distortions derived from the chemical shift or the field inhomogeneity. Importantly, as the T2* map is well positioned, the species signal in borders is correctly estimated. Considering intraecho time variations in a complete signal model in k-space for separating species yields superior estimation of the variables of interest when compared to existing methods. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
KW - chemical species separation
KW - fat and water
KW - field inhomogeneities
KW - magnetic resonance imaging
KW - off-resonance correction
UR - http://www.scopus.com/inward/record.url?scp=84863821147&partnerID=8YFLogxK
U2 - 10.1002/mrm.23237
DO - 10.1002/mrm.23237
M3 - Article
C2 - 22212998
AN - SCOPUS:84863821147
VL - 68
SP - 400
EP - 408
JO - Magnetic Resonance in Medicine
JF - Magnetic Resonance in Medicine
SN - 0740-3194
IS - 2
ER -