TY - JOUR
T1 - CARETestLung
T2 - A mechanical test lung with Configurable airway Resistance, lung Elastance, and breathing efforts
AU - Tay, Wei Yang
AU - Ang, Christopher Yew Shuen
AU - Chiew, Yeong Shiong
AU - Geoffrey Chase, J.
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024/9
Y1 - 2024/9
N2 - A mechanical test lung is a crucial tool in accurately simulating patient-specific physiological responses of patients undergoing mechanical ventilation (MV), which, in turn, offer clinicians insight into lung mechanics during MV. In particular, it can be used to facilitate better methods to identify optimal ventilator settings, modes for individual patients by providing a platform to experiment with different MV settings. This addresses the challenge of optimising MV settings caused by variability in pathological conditions and the progression of respiratory disease over time within patients. However, the accessibility and cost of versatile test lungs limit widespread adoption in clinical settings, underscoring the need for affordable alternatives. This paper presents detailed instructions for the design and construction of a replicable, cost-effective mechanical test lung. The design features 3 subsystems: 1) the lung compartment; 2) the airway; and 3) a spontaneous breathing system. A detailed tests series shows its ability to replicate clinically realistic lung elastance values ranging from 25 to 85 cmH2O/L and airway resistance values from 10 to 45 cmH2O·s/L. It can also simulate a range of clinically realistic spontaneous breathing patterns. These capabilities yield pressure and flow ventilation data comparable to certified clinical test lungs across diverse scenarios, as well as matching clinically observed behaviours and dynamics. This accessible and versatile test lung offers valuable opportunities for optimising MV settings and advancing patient care, as well as its use in developing a range of physiological models for model-based decision support.
AB - A mechanical test lung is a crucial tool in accurately simulating patient-specific physiological responses of patients undergoing mechanical ventilation (MV), which, in turn, offer clinicians insight into lung mechanics during MV. In particular, it can be used to facilitate better methods to identify optimal ventilator settings, modes for individual patients by providing a platform to experiment with different MV settings. This addresses the challenge of optimising MV settings caused by variability in pathological conditions and the progression of respiratory disease over time within patients. However, the accessibility and cost of versatile test lungs limit widespread adoption in clinical settings, underscoring the need for affordable alternatives. This paper presents detailed instructions for the design and construction of a replicable, cost-effective mechanical test lung. The design features 3 subsystems: 1) the lung compartment; 2) the airway; and 3) a spontaneous breathing system. A detailed tests series shows its ability to replicate clinically realistic lung elastance values ranging from 25 to 85 cmH2O/L and airway resistance values from 10 to 45 cmH2O·s/L. It can also simulate a range of clinically realistic spontaneous breathing patterns. These capabilities yield pressure and flow ventilation data comparable to certified clinical test lungs across diverse scenarios, as well as matching clinically observed behaviours and dynamics. This accessible and versatile test lung offers valuable opportunities for optimising MV settings and advancing patient care, as well as its use in developing a range of physiological models for model-based decision support.
KW - Mechanical test lung
KW - Mechanical ventilation
KW - Spontaneous breathing
UR - https://www.scopus.com/pages/publications/85202524172
U2 - 10.1016/j.ohx.2024.e00579
DO - 10.1016/j.ohx.2024.e00579
M3 - Article
AN - SCOPUS:85202524172
SN - 2468-0672
VL - 19
JO - HardwareX
JF - HardwareX
M1 - e00579
ER -