TY - JOUR
T1 - Automatic Evaluation Method for Functional Movement Screening Based on Multi-Scale Lightweight 3D Convolution and an Encoder–Decoder
AU - Lin, Xiuchun
AU - Liu, Yichao
AU - Feng, Chen
AU - Chen, Zhide
AU - Yang, Xu
AU - Cui, Hui
N1 - Funding Information:
This work was supported in part by the National Natural Science Foundation of China (62277010, 62302203), Science and Technology Project of Fuzhou Institute of Oceanography (2023F03), Fuzhou-Xiamen-Quanzhou National Independent Innovation Demonstration Zone Collaborative Innovation Platform Project (2022FX6), Fujian Province Education Science 14th Five-Year Plan 2022 Ollaborative Innovation Special Project (Fjxczx22-450), Fujian Institute of Education Special Research Project on Training Reform (2023PX-06) and the Fujian Provincial Health Commission Technology Plan Project (2021CXA001).
Publisher Copyright:
© 2024 by the authors.
PY - 2024/5/7
Y1 - 2024/5/7
N2 - Functional Movement Screening (FMS) is a test used to evaluate fundamental movement patterns in the human body and identify functional limitations. However, the challenge of carrying out an automated assessment of FMS is that complex human movements are difficult to model accurately and efficiently. To address this challenge, this paper proposes an automatic evaluation method for FMS based on a multi-scale lightweight 3D convolution encoder–decoder (ML3D-ED) architecture. This method adopts a self-built multi-scale lightweight 3D convolution architecture to extract features from videos. The extracted features are then processed using an encoder–decoder architecture and probabilistic integration technique to effectively predict the final score distribution. This architecture, compared with the traditional Two-Stream Inflated 3D ConvNet (I3D) network, offers a better performance and accuracy in capturing advanced human movement features in temporal and spatial dimensions. Specifically, the ML3D-ED backbone network reduces the number of parameters by 59.5% and the computational cost by 77.7% when compared to I3D. Experiments have shown that ML3D-ED achieves an accuracy of 93.33% on public datasets, demonstrating an improvement of approximately 9% over the best existing method. This outcome demonstrates the effectiveness of and advancements made by the ML3D-ED architecture and probabilistic integration technique in extracting advanced human movement features and evaluating functional movements.
AB - Functional Movement Screening (FMS) is a test used to evaluate fundamental movement patterns in the human body and identify functional limitations. However, the challenge of carrying out an automated assessment of FMS is that complex human movements are difficult to model accurately and efficiently. To address this challenge, this paper proposes an automatic evaluation method for FMS based on a multi-scale lightweight 3D convolution encoder–decoder (ML3D-ED) architecture. This method adopts a self-built multi-scale lightweight 3D convolution architecture to extract features from videos. The extracted features are then processed using an encoder–decoder architecture and probabilistic integration technique to effectively predict the final score distribution. This architecture, compared with the traditional Two-Stream Inflated 3D ConvNet (I3D) network, offers a better performance and accuracy in capturing advanced human movement features in temporal and spatial dimensions. Specifically, the ML3D-ED backbone network reduces the number of parameters by 59.5% and the computational cost by 77.7% when compared to I3D. Experiments have shown that ML3D-ED achieves an accuracy of 93.33% on public datasets, demonstrating an improvement of approximately 9% over the best existing method. This outcome demonstrates the effectiveness of and advancements made by the ML3D-ED architecture and probabilistic integration technique in extracting advanced human movement features and evaluating functional movements.
KW - 3D convolution
KW - automatic evaluation method
KW - encoder–decoder
KW - functional movement screening
KW - human movement feature
UR - https://www.scopus.com/pages/publications/85194265801
U2 - 10.3390/electronics13101813
DO - 10.3390/electronics13101813
M3 - Article
AN - SCOPUS:85194265801
SN - 2079-9292
VL - 13
JO - Electronics (Switzerland)
JF - Electronics (Switzerland)
IS - 10
M1 - 1813
ER -