TY - JOUR
T1 - Automated measurement of inter-arytenoid distance on 4D laryngeal CT
T2 - A validation study
AU - Ma, Andrew
AU - Desai, Nandakishor
AU - Lau, Kenneth K.
AU - Palaniswami, Marimuthu
AU - O’Brien, Terence J.
AU - Palaniswami, Paari
AU - Thyagarajan, Dominic
N1 - Funding Information:
A. Ma received salary from Ipsen Biopharmaceuticals as support for a Movement Disorders Fellowship and received support from an Australian Government Research Training Program (RTP) Scholarship. The funders provided support in the form of salaries for author AM, but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.
Publisher Copyright:
© 2023 Ma et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2023/1
Y1 - 2023/1
N2 - Changes to the voice are prevalent and occur early in Parkinson’s disease. Correlates of these voice changes on four-dimensional laryngeal computed-tomography imaging, such as the inter-arytenoid distance, are promising biomarkers of the disease’s presence and severity. However, manual measurement of the inter-arytenoid distance is a laborious process, limiting its feasibility in large-scale research and clinical settings. Automated methods of measurement provide a solution. Here, we present a machine-learning module which determines the inter-arytenoid distance in an automated manner. We obtained automated inter-arytenoid distance readings on imaging from participants with Parkinson’s disease as well as healthy controls, and then validated these against manually derived estimates. On a modified Bland-Altman analysis, we found a mean bias of 1.52 mm (95% limits of agreement -1.7 to 4.7 mm) between the automated and manual techniques, which improves to a mean bias of 0.52 mm (95% limits of agreement -1.9 to 2.9 mm) when variability due to differences in slice selection between the automated and manual methods are removed. Our results demonstrate that estimates of the inter-arytenoid distance with our automated machine-learning module are accurate, and represents a promising tool to be utilized in future work studying the laryngeal changes in Parkinson’s disease.
AB - Changes to the voice are prevalent and occur early in Parkinson’s disease. Correlates of these voice changes on four-dimensional laryngeal computed-tomography imaging, such as the inter-arytenoid distance, are promising biomarkers of the disease’s presence and severity. However, manual measurement of the inter-arytenoid distance is a laborious process, limiting its feasibility in large-scale research and clinical settings. Automated methods of measurement provide a solution. Here, we present a machine-learning module which determines the inter-arytenoid distance in an automated manner. We obtained automated inter-arytenoid distance readings on imaging from participants with Parkinson’s disease as well as healthy controls, and then validated these against manually derived estimates. On a modified Bland-Altman analysis, we found a mean bias of 1.52 mm (95% limits of agreement -1.7 to 4.7 mm) between the automated and manual techniques, which improves to a mean bias of 0.52 mm (95% limits of agreement -1.9 to 2.9 mm) when variability due to differences in slice selection between the automated and manual methods are removed. Our results demonstrate that estimates of the inter-arytenoid distance with our automated machine-learning module are accurate, and represents a promising tool to be utilized in future work studying the laryngeal changes in Parkinson’s disease.
UR - http://www.scopus.com/inward/record.url?scp=85146531973&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0279927
DO - 10.1371/journal.pone.0279927
M3 - Article
C2 - 36652423
AN - SCOPUS:85146531973
SN - 1932-6203
VL - 18
JO - PLoS ONE
JF - PLoS ONE
IS - 1
M1 - e0279927
ER -