Analysing concurrent transcranial magnetic stimulation and electroencephalographic data: A review and introduction to the open-source TESA software

Nigel C. Rogasch, Caley Sullivan, Richard H. Thomson, Nathan S. Rose, Neil W. Bailey, Paul B. Fitzgerald, Faranak Farzan, Julio C. Hernandez-Pavon

Research output: Contribution to journalReview ArticleResearchpeer-review

Abstract

The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS–EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS–EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS–EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS–EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS–EEG research.

Original languageEnglish
Pages (from-to)934-951
Number of pages18
JournalNeuroImage
Volume147
DOIs
Publication statusPublished - 15 Feb 2017

Keywords

  • Artifacts
  • EEGLAB
  • Electroencephalography
  • Transcranial magnetic stimulation

Cite this

@article{35fc6c100b3b43c7a41d42e35cbde4c2,
title = "Analysing concurrent transcranial magnetic stimulation and electroencephalographic data: A review and introduction to the open-source TESA software",
abstract = "The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS–EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS–EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS–EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS–EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS–EEG research.",
keywords = "Artifacts, EEGLAB, Electroencephalography, Transcranial magnetic stimulation",
author = "Rogasch, {Nigel C.} and Caley Sullivan and Thomson, {Richard H.} and Rose, {Nathan S.} and Bailey, {Neil W.} and Fitzgerald, {Paul B.} and Faranak Farzan and Hernandez-Pavon, {Julio C.}",
year = "2017",
month = "2",
day = "15",
doi = "10.1016/j.neuroimage.2016.10.031",
language = "English",
volume = "147",
pages = "934--951",
journal = "NeuroImage",
issn = "1053-8119",
publisher = "Elsevier",

}

Analysing concurrent transcranial magnetic stimulation and electroencephalographic data : A review and introduction to the open-source TESA software. / Rogasch, Nigel C.; Sullivan, Caley; Thomson, Richard H.; Rose, Nathan S.; Bailey, Neil W.; Fitzgerald, Paul B.; Farzan, Faranak; Hernandez-Pavon, Julio C.

In: NeuroImage, Vol. 147, 15.02.2017, p. 934-951.

Research output: Contribution to journalReview ArticleResearchpeer-review

TY - JOUR

T1 - Analysing concurrent transcranial magnetic stimulation and electroencephalographic data

T2 - A review and introduction to the open-source TESA software

AU - Rogasch, Nigel C.

AU - Sullivan, Caley

AU - Thomson, Richard H.

AU - Rose, Nathan S.

AU - Bailey, Neil W.

AU - Fitzgerald, Paul B.

AU - Farzan, Faranak

AU - Hernandez-Pavon, Julio C.

PY - 2017/2/15

Y1 - 2017/2/15

N2 - The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS–EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS–EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS–EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS–EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS–EEG research.

AB - The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS–EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS–EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS–EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS–EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS–EEG research.

KW - Artifacts

KW - EEGLAB

KW - Electroencephalography

KW - Transcranial magnetic stimulation

UR - http://www.scopus.com/inward/record.url?scp=85006511322&partnerID=8YFLogxK

U2 - 10.1016/j.neuroimage.2016.10.031

DO - 10.1016/j.neuroimage.2016.10.031

M3 - Review Article

VL - 147

SP - 934

EP - 951

JO - NeuroImage

JF - NeuroImage

SN - 1053-8119

ER -