TY - JOUR
T1 - A comparison of estimates of glomerular filtration in critically ill patients with augmented renal clearance
AU - Baptista, João Pedro
AU - Udy, Andrew A.
AU - Sousa, Eduardo
AU - Pimentel, Jorge
AU - Wang, Lisa
AU - Roberts, Jason A.
AU - Lipman, Jeffrey
N1 - M1 - 3
Baptista, Joao Pedro Udy, Andrew A Sousa, Eduardo Pimentel, Jorge Wang, Lisa Roberts, Jason A Lipman, Jeffrey eng Comparative Study Multicenter Study Research Support, Non-U.S. Gov't England London, England 2011/06/10 06:00 Crit Care. 2011 Jun 8;15(3):R139. doi: 10.1186/cc10262.
PY - 2011/6/8
Y1 - 2011/6/8
N2 - INTRODUCTION: Increasingly, derived estimates of glomerular filtration, such as the modification of diet in renal disease (MDRD) equation and Cockcroft-Gault (CG) formula are being employed in the intensive care unit (ICU). To date, these estimates have not been rigorously validated in those with augmented clearances, resulting in potentially inaccurate drug prescription. METHODS: Post-hoc analysis of prospectively collected data in two tertiary level ICU's in Australia and Portugal. Patients with normal serum creatinine concentrations manifesting augmented renal clearance (ARC) (measured creatinine clearance (CLCR) > 130 ml/min/1.73 m2) were identified by chart review. Comparison between measured values and MDRD and CG estimates were then undertaken. Spearman correlation coefficients (rs) were calculated to determine goodness of fit, and precision and bias were assessed using Bland-Altman plots. RESULTS: Eighty-six patients were included in analysis. The median [IQR] measured CLCR was 162 [145-190] ml/min/1.73 m2, as compared to 135 [116-171], 93 [83-110], 124[102-154], and 108 [87-135] ml/min/1.73 m2 estimated by CG, modified CG, 4-variable MDRD and 6-variable MDRD formulae. All of the equations significantly under-estimated the measured value, with CG displaying the smallest bias (39 ml/min/1.73 m2). Although a moderate correlation was noted between CLCR and CG (rs = 0.26, P = 0.017) and 4-variable MDRD (rs = 0.22, P = 0.047), neither had acceptable precision for clinical application in this setting. CG estimates had the highest sensitivity for correctly identifying patients with ARC (62%). CONCLUSIONS: Derived estimates of GFR are inaccurate in the setting of ARC, and should be interpreted with caution by the physician. A measured CLCR should be performed to accurately guide drug dosing.
AB - INTRODUCTION: Increasingly, derived estimates of glomerular filtration, such as the modification of diet in renal disease (MDRD) equation and Cockcroft-Gault (CG) formula are being employed in the intensive care unit (ICU). To date, these estimates have not been rigorously validated in those with augmented clearances, resulting in potentially inaccurate drug prescription. METHODS: Post-hoc analysis of prospectively collected data in two tertiary level ICU's in Australia and Portugal. Patients with normal serum creatinine concentrations manifesting augmented renal clearance (ARC) (measured creatinine clearance (CLCR) > 130 ml/min/1.73 m2) were identified by chart review. Comparison between measured values and MDRD and CG estimates were then undertaken. Spearman correlation coefficients (rs) were calculated to determine goodness of fit, and precision and bias were assessed using Bland-Altman plots. RESULTS: Eighty-six patients were included in analysis. The median [IQR] measured CLCR was 162 [145-190] ml/min/1.73 m2, as compared to 135 [116-171], 93 [83-110], 124[102-154], and 108 [87-135] ml/min/1.73 m2 estimated by CG, modified CG, 4-variable MDRD and 6-variable MDRD formulae. All of the equations significantly under-estimated the measured value, with CG displaying the smallest bias (39 ml/min/1.73 m2). Although a moderate correlation was noted between CLCR and CG (rs = 0.26, P = 0.017) and 4-variable MDRD (rs = 0.22, P = 0.047), neither had acceptable precision for clinical application in this setting. CG estimates had the highest sensitivity for correctly identifying patients with ARC (62%). CONCLUSIONS: Derived estimates of GFR are inaccurate in the setting of ARC, and should be interpreted with caution by the physician. A measured CLCR should be performed to accurately guide drug dosing.
KW - Adult Aged Cohort Studies Critical Illness/therapy Female Glomerular Filtration Rate/physiology Humans Intensive Care Units/standards Kidney Function Tests/methods/standards Male Metabolic Clearance Rate/physiology Middle Aged Prospective Studies Young Ad
U2 - 10.1186/cc10262
DO - 10.1186/cc10262
M3 - Article
SN - 1466-609X
VL - 15
JO - Critical Care
JF - Critical Care
M1 - R139
ER -