Abstract

Hybrid fabricated columns (HFCs) consisting of mild-steel thin plates connected to ultra-high strength thin-walled tubes at corners have exhibited superior performance compared to the equivalent conventional tubular columns. The higher load-bearing capacity, energy absorption, and post-buckling strength of these columns provide designers with new possibilities in the construction of high-rise buildings. Although several studies have been conducted on these columns, the connection between I-beams and this type of column is challenging. In this paper, using 3-D finite element modelling a numerical study is conducted to compare the behaviour of recently patented bolted modular M-HFC connection between I-beams and HFCs with the welded non-modular type of this connection (called as W-HFC). The performance of the W-HFC connection is also compared with four different types of common conventional connections currently in use in the industry. Moreover, a topology optimisation has been performed on the M-HFC connection in order to reduce the overall weight of the connection components while keeping the moment- rotation characteristics of the connection as close as possible to the originally proposed connection.

Original languageEnglish
Pages (from-to)235-258
Number of pages24
JournalThin-Walled Structures
Volume127
DOIs
Publication statusPublished - 1 Jun 2018

Keywords

  • Connection
  • Hybrid fabricated column
  • Moment rotation
  • Numerical study
  • Topology optimisation
  • Ultra-high strength

Cite this

Sadeghi, Seyed Nima ; Heidarpour, Amin ; Zhao, Xiao-Ling ; Al-Mahaidi, Riadh. / A comparative numerical study on the innovative I-beam to thin-walled hybrid fabricated column connection. In: Thin-Walled Structures. 2018 ; Vol. 127. pp. 235-258.
@article{2901416ec3c5465c8a9192fecf646411,
title = "A comparative numerical study on the innovative I-beam to thin-walled hybrid fabricated column connection",
abstract = "Hybrid fabricated columns (HFCs) consisting of mild-steel thin plates connected to ultra-high strength thin-walled tubes at corners have exhibited superior performance compared to the equivalent conventional tubular columns. The higher load-bearing capacity, energy absorption, and post-buckling strength of these columns provide designers with new possibilities in the construction of high-rise buildings. Although several studies have been conducted on these columns, the connection between I-beams and this type of column is challenging. In this paper, using 3-D finite element modelling a numerical study is conducted to compare the behaviour of recently patented bolted modular M-HFC connection between I-beams and HFCs with the welded non-modular type of this connection (called as W-HFC). The performance of the W-HFC connection is also compared with four different types of common conventional connections currently in use in the industry. Moreover, a topology optimisation has been performed on the M-HFC connection in order to reduce the overall weight of the connection components while keeping the moment- rotation characteristics of the connection as close as possible to the originally proposed connection.",
keywords = "Connection, Hybrid fabricated column, Moment rotation, Numerical study, Topology optimisation, Ultra-high strength",
author = "Sadeghi, {Seyed Nima} and Amin Heidarpour and Xiao-Ling Zhao and Riadh Al-Mahaidi",
year = "2018",
month = "6",
day = "1",
doi = "10.1016/j.tws.2018.02.007",
language = "English",
volume = "127",
pages = "235--258",
journal = "Thin-Walled Structures",
issn = "0263-8231",
publisher = "Elsevier",

}

A comparative numerical study on the innovative I-beam to thin-walled hybrid fabricated column connection. / Sadeghi, Seyed Nima; Heidarpour, Amin; Zhao, Xiao-Ling; Al-Mahaidi, Riadh.

In: Thin-Walled Structures, Vol. 127, 01.06.2018, p. 235-258.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - A comparative numerical study on the innovative I-beam to thin-walled hybrid fabricated column connection

AU - Sadeghi, Seyed Nima

AU - Heidarpour, Amin

AU - Zhao, Xiao-Ling

AU - Al-Mahaidi, Riadh

PY - 2018/6/1

Y1 - 2018/6/1

N2 - Hybrid fabricated columns (HFCs) consisting of mild-steel thin plates connected to ultra-high strength thin-walled tubes at corners have exhibited superior performance compared to the equivalent conventional tubular columns. The higher load-bearing capacity, energy absorption, and post-buckling strength of these columns provide designers with new possibilities in the construction of high-rise buildings. Although several studies have been conducted on these columns, the connection between I-beams and this type of column is challenging. In this paper, using 3-D finite element modelling a numerical study is conducted to compare the behaviour of recently patented bolted modular M-HFC connection between I-beams and HFCs with the welded non-modular type of this connection (called as W-HFC). The performance of the W-HFC connection is also compared with four different types of common conventional connections currently in use in the industry. Moreover, a topology optimisation has been performed on the M-HFC connection in order to reduce the overall weight of the connection components while keeping the moment- rotation characteristics of the connection as close as possible to the originally proposed connection.

AB - Hybrid fabricated columns (HFCs) consisting of mild-steel thin plates connected to ultra-high strength thin-walled tubes at corners have exhibited superior performance compared to the equivalent conventional tubular columns. The higher load-bearing capacity, energy absorption, and post-buckling strength of these columns provide designers with new possibilities in the construction of high-rise buildings. Although several studies have been conducted on these columns, the connection between I-beams and this type of column is challenging. In this paper, using 3-D finite element modelling a numerical study is conducted to compare the behaviour of recently patented bolted modular M-HFC connection between I-beams and HFCs with the welded non-modular type of this connection (called as W-HFC). The performance of the W-HFC connection is also compared with four different types of common conventional connections currently in use in the industry. Moreover, a topology optimisation has been performed on the M-HFC connection in order to reduce the overall weight of the connection components while keeping the moment- rotation characteristics of the connection as close as possible to the originally proposed connection.

KW - Connection

KW - Hybrid fabricated column

KW - Moment rotation

KW - Numerical study

KW - Topology optimisation

KW - Ultra-high strength

UR - http://www.scopus.com/inward/record.url?scp=85042104927&partnerID=8YFLogxK

U2 - 10.1016/j.tws.2018.02.007

DO - 10.1016/j.tws.2018.02.007

M3 - Article

VL - 127

SP - 235

EP - 258

JO - Thin-Walled Structures

JF - Thin-Walled Structures

SN - 0263-8231

ER -